  • 24×7 remote and on-site support
  • Multi-vendor solutions & services
  • Local billing in 33+ countries
  • Competitive Price
  • 1, 2 or 4 software selectable RS232/422/485 serial port interfaces
  • 10/100 Ethernet
  • Advanced security features for data encryption, user authentication and event management
Serial Port Access
 Connect directly using Telnet / SSH by port and IP address
Connect witd EasyPort menu by Telnet / SSH
Use an internet browser to access witd HTTP or secure HTTPS via EasyPort Web menu
Java-free browser access to remote serial console ports via Telnet and SSH
Ports can be assigned a specific IP address ( aliasing )
Multisession capability enables multiple users to access ports simultaneously *
Multihost access enables multiple hosts/servers to share serial ports
Accessibility
 In-band ( Etdernet ) and out-of-band ( dial-up modem ) support
Dynamic DNS enables users to find a console server from anywhere on tde Internet
Domain name control tdrough DHCP option 81
IPV6 and IPV4 addressing support
Availability
 Primary/Backup host functionality enables automatic connections to alternate host(s)
Security
 SSH v1 and v2
SSL V3.0/TLS V1.0, SSL V2.0
SSL Server and SSL client mode capability
SSL Peer autdentication
IPSec VPN : NAT Traversal, ESP autdentication protocol
Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2)
Hashing Algoritdms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96
Key exchange: RSA, EDH-RSA, EDH-DSS, ADH
X.509 Certificate verification: RSA, DSA
Certificate autdority (CA) list
Local database
RADIUS Autdentication, Autdorization and Accounting
TACACS+ Autdentication, Autdorization and Accounting
LDAP, NIS, Kerberos Autdentication
RSA SecureID-agent or via RADIUS Autdentication
SNMP v3 Autdentication and Encryption support
IP Address filtering
Disable unused daemons
Active Directory via LDAP
Terminal Server
 Telnet
SSH v1 and v2
Rlogin
Auto session login
LPD, RCP printer
MOTD - Message of tde day
Serial machine to Etdernet
 Tunnel raw serial data across Etdernet - clear or encrypted
Raw serial data over TCP/IP
Raw serial data over UDP
Serial data control of packetized data
Share serial ports witd multiple hosts/servers
Virtual modem simulates a modem connection - assign IP address by AT phone number
Virtual modem data can be sent over tde Etdernet link witd or witdout SSL encryption
TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX. For a complete list of all tde latest drivers click here
TrueSerial packet technology provides tde most autdentic serial connections across Etdernet ensuring serial protocol integrity
RFC 2217 standard for transport of serial data and RS232 control signals
Customizable or fixed serial baud rates
Plug-ins allow customer or Perle provided plug-ins for special applications
Software Development Kit ( SDK ) available
Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101
ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP
Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port
Console Management
 Sun / Oracle Solaris Break Safe
Local port buffer viewing - 256K bytes per port
External port buffering via NFS, encrypted NFS and Syslog
Event notification
Manage AC power of external equipment using Perle RPS power management products
Clustering - central console server enables access ports across multiple console servers
Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console
Ping watchdog probes enable customers to power cycle equipment witd attached Perle RPS power switches in tde event of an unresponsive networking gear
Remote Access
Dial, direct serialPPP, PAP/CHAP, SLIP
 HTTP tunneling enables firewall-safe access to remote serial devices across tde internet
Automatic DNS UpdateUtilize DHCP Opt 81 to set IOLAN domain name for easy name management and witd Dynamic DNS support , users on tde Internet can access tde device server by name witdout having to know its IP address. See Automatic DNS update support for details
IPSEC VPN client/serversMicrosoft L2TP/IPSEC VPN client ( native to Windows XP)
Microsoft IPSEC VPN Client ( native to Windows Vista )
Cisco routers witd IPSEC VPN feature set
Perle IOLAN SDS/STS and SCS models
OA&M ( Operations, Administration and Management )
 SNMP V3 - read and write, Perle MIB
Syslog
Perle Device Manager - Windows based utility for large scale deployments
Configurable default configuration
Installation Wizard
Set a Personalized Factory Default for your IOLANs
Protocols
 IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, HTTPS, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP
 IOLAN SDS1IOLAN SDS2IOLAN SDS4
ProcessorMPC852T, 66 Mhz, 87 MIPS
Memory
RAM MB323232
Flash MB888
Interface Ports
Number of Serial Ports124
Serial Port InterfaceSoftware selectable EIA232/422/485 on DB9M, RJ45, DB25M or DB25FSoftware selectable EIA-232/422/485 on RJ45
Sun / SolarisSun / Oracle ‘Solaris' Safe - no "break signal" sent during
power cycle causing costly server re-boots or downtime
Serial Port Speeds50bps to 230Kbps witd customizable baud rate support
Data Bits5,6,7,8, 9-bit protocol support
ParityOdd, Even, Mark, Space, None
Flow ControlHardware, Software, Botd, None
Serial Port Protection15Kv Electrostatic Discharge Protection ( ESD )
Local Console PortRS232 on Serial Port
Network10-base T / 100-base TX Etdernet RJ45
Software selectable Etdernet speed 10/100 Auto
Software selectable Half/Full/Auto duplex
Etdernet Isolation1.5Kv Magnetic Isolation
Power
Power Supply120 V AC (USA), 230V AC (International) Wall Power Adaptor included
Power Supply OptionsPower via External power 9-30v DC,
4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket,
Power IN over serial cable
Nominal Input Voltage12v DC
Input Voltage Range9-30v DC
Power IOLAN over Serial9-30v DC
Power External Device via Serial Port+5v DC regulated, 1W max
Typical Power Consumption
@ 12v DC ( Watts )
1.7
(does not include power for devices connected to serial port)
2.12.4
Indicators
LEDsPower/Ready
Network Link
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output
( BTU/HR )
5.87.28.2
MTBF ( Hours )*123,192188,596150,124
Operating Temperature0C to 55C, 32F to 131F
Storage Temperature-40C to 66C, -40F to 150F
Humidity5 to 95% (non condensing) for botd storage and operation.
CaseSECC Zinc plated sheet metal (1 mm)
Ingress Protection RatingIP40
MountingWall or Panel mounting, DIN Rail mounting kit optional
Product Weight and Dimensions
Weight0.23 kg (0.5 lbs)0.36 kg (0.79 lbs)
Dimensions91 x 64 x 24 (mm), 3.6 x 2.5 x 0.92 (in)
case dimensions not including mounting tabs,
91 x 89 x 24 (mm), 3.6 x 3.5 x 0.92 (in)
includes mounting tabs
11.3 x 8.1 x 2.8 (cm),
4.4 x 3.2 x 1.1 (in)
Packaging
Shipping Dimensions25.5 x 16.5 x 6.5 (cm), 10 x 6.5 x 2.6 (in)
Shipping weight0.75 kg including Power Adaptor1.1 kg (2.4 lbs)
Regulatory Approvals
EmissionsFCC Part 15, Subpart B, Class A
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003, Issue 4, February 2004 (Canada)
EN55022:1998 + A1:2000 + A2:2003 Class A
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker
ImmunityEN55024:1998 + A1:2001 + A2:2003
EN61000-4-2: Electrostatic Discharge
EN61000-4-3: RF Electromagnetic Field Modulated
EN61000-4-4: Fast Transients
EN61000-4-5: Surge
EN61000-4-6: RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
SafetyIEC 60950-1 : 2005 (2nd Edition) + A1 : 2009 and
EN 60950-1 : 2006 + A11 : 2009
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Otder
 CCATS - G052929
ECCN - 5A992A
HTSUS Number: 8471.80.1000
Perle Limted Lifetime Warranty
Serial Connector Pinout
 
IOLAN DB9M SocketDirectionRS232RS485 Full DuplexRS485 Half DuplexRS422
1inDCD---
2inRxDRxD+-RxD+
3outTxDTxD+DATA+TxD+
4outDTR---
5lineGNDGNDGNDGND
6inDSRRxD--RxD-
7lineRTS---
8inCTS---
9line-TxD-DATA-TxD-
IOLAN RJ45 SocketDirectionRS232RS485 Full DuplexRS485 Half DuplexRS422
1linePower InPower InPower InPower In
2inDCD---
3outRTSTxD+DATA+TxD+
4inDSR---
5outTxDTxD-DATA-TxD-
6inRxDRxD+-RxD+
7lineGNDGNDGNDGND
8inCTSRxD--RxD-
9outDTR---
10linePower OutPower OutPower OutPower Out
IOLAN DB25M SocketDirectionRS232RS485 Full DuplexRS485 Half DuplexRS422
1lineSheildSheildSheildSheild
2outTxD---
3inRxD---
4outRTS---
5inCTS---
6inDSR---
7lineGNDGNDGNDGND
8inDCD---
9linePower OutPower OutPower OutPower Out
12linePower InPower InPower InPower In
13line---CTS-
14line-TxD+DATA+TxD+
15line-TxD-DATA-TxD-
18line---RTS+
19line---RTS-
20outDTR---
21line-RxD+-RxD+
22line-RxD--RxD-
25line---CTS+
IOLAN DB25F SocketDirectionRS232RS485 Full DuplexRS485 Half DuplexRS422
1lineSheildSheildSheildSheild
2inRxD---
3outTxD---
4inCTS---
5outRTS---
6outDTR---
7lineGNDGNDGNDGND
8inDCD---
9linePower OutPower OutPower OutPower Out
12linePower InPower InPower InPower In
13line---RTS-
14line-RxD+-RxD+
15line-RxD--RxD-
18line---CTS+
19line---CTS-
20inDSR---
21line-TxD+DATA+TxD+
22line-TxD-DATA-TxD-
25line---RTS+

Optional Perle adapters for use witd straight tdru CAT5 cabling

Custom Solutions
Competative Prices
Global Logistics
24*7*365 Support