Vertiv Liebert GXT MT+ 1/2/3Kva Double Conversion
In stock
SKU:
GXTMT+1/2/3 kVA
- 24×7 remote and on-site support
- Multi-vendor solutions & services
- Local billing in 33+ countries
- Competitive Price
Liebert GXT MT+ Series systems is true double conversion online UPS systems designed to provide with a capacity of 1/2/3 kVA. Liebert GXT MT+ units feature total isolation of the load from the mains - isolating input and output sections, and making the systems ideal for Data Networks / Small Data Centers/VOIP Applications application. The units support hot standby configuration, making them suited for critical applications like banks
- IGBT Based Rectifier
- True Online Double Conversion with DSP Control Technology for High Performance and Reliability.
- New Graphical LCD Display Provides UPS Data, Alarms and Helps in faults diagnostics and trouble shooting.
- Double Conversion Efficiency upto 90%.
- Active Input Power Factor Correction 0.99.
- 0.8 Output Power Factor.
- Wide Input Voltage window (110 - 280 Vac) for Indian Environmental Condition and for Optimized Battery Performance.
- Configurable Output Voltage (200/208/220/230/240 Vac.)
- Generator Compatible with Wide Input Frequency Range (40 Hz-70 Hz).
- 4 Stage Extendable Charging Design for optimized Battery Performance.
- Adjustable Battery Charging Current 1/2/4/6 Amps according to Battery Capacity and Rating.
- 50/60 Hz Automatic Frequency Converter Mode.
- Intelligent Monitoring with Standard RS232/USB Port Plus Slot Available for RS485/Dry Contact/SNMP Card.
- Inbuilt OVCD.
CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W |
INPUT |
Nominal Voltage 230 Vac |
110 VAC ± 3% at 50% Load |
176 VAC ± 3% at 100% Load |
120 VAC ± 3% at 50% Load |
186 VAC ± 3% at 100% Load |
High Line Loss 280 VAC ± 3% |
High Line Comeback 270 VAC ± 3% |
Frequency Range 40 Hz ~ 70 Hz |
Power Factor ≥ 0.99 @ 100% load |
OUTPUT |
Nominal Voltage 208/220/230/240VAC |
AC Voltage Regulation ± 1% |
Frequency Range (Synchronized Range) 46Hz ~ 54 Hz or 56Hz ~ 64 Hz |
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
Current Crest Ratio 3:1 (max.) |
Harmonic Distortion ≤ 3 % THD (Linear Load), ≤ 7 % THD (Non-linear Load) |
Transfer Time Bypass to Inverter (Line mode) Zero |
Inverter to Bypass (Line mode) 4 ms (Typical) |
Waveform (Batt. Mode) Pure Sinewave |
EFFICIENCY on AC to AC mode@ 100% load. 88% 88% 90% |
Inbuilt Isolation Transformer No |
BATTERY |
Battery Type 12V/ 9 AH 12V/ 9 AH 12V/ 9 AH |
Numbers 2 4 6 |
Typical Recharge Time 4 hours recover to 90% capacity |
Charging Current (max.) 1.0 A |
Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1% |
Battery Type Depending on the capacity of external batteries |
Numbers 3 6 6 |
Charging Current 1.0A/2.0A/4.00.0A, 6.0A default |
Float Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% "82.1 VDC *1% |
INDICATORS |
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
ALARM |
Battery Mode Sounding every 4 seconds |
Low Battery Sounding every second |
Overload Sounding twice every second |
Fault Countinously sounding |
PHYSICAL |
Standard Run Dimension, D x W x H (mm) 282 x 145 x 220 397 x145 x220 421 x 190 x 318 Model Net Weight (kgs) 9.8 17 27.6 Long Run Dimension, O x W x H (mm) 282 x 145 x 220 397 x145 x220 Model* Net Weight (kgs) 4.1 6.8 7.4 ENVIRONMENT Operation Humidity and Temperature 20-90 % RH @ 0- 45°C (non-condensing) Noise Level Less than 50dBA @ 1 Meter MANAGEMENT Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC Optional SNMP Power management from SNMP manager and web browser |