APC NetShelter Rack PDU Advanced, Switched Metered Outlet, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet
- 24×7 remote and on-site support
- Multi-vendor solutions & services
- Local billing in 33+ countries
- Competitive Price
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps.
Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to
Main | Main Input Voltage 3 phase |
Product or Component Type PDU | |
Main Output Voltage 240 V | |
Plug standard IEC 60309 60 A 3P+N+PE | |
Number of rack unit 0U | |
Cable length 5.91 ft (1.8 m) | |
Communication port protocol 1000BASE-T | |
10/100BASE-T | |
Physical | Color Black |
Height 71.89 in (182.6 cm) | |
Width 2.20 in (5.6 cm) | |
Depth 2.95 in (7.5 cm) | |
Net Weight 28.00 lb(US) (12.7 kg) | |
Mounting Location Side | |
Mounting preference No preference | |
Mounting Mode Rack-mounted | |
Input | Line Rated Current 48 A |
Acceptable Input Voltage 200...240 V | |
346...415 V | |
Input current limits 60 A | |
Load Capacity 34600 VA | |
Input Frequency 50/60 Hz | |
Output | Number of power socket outlets 21 C13/C15/C19/C21 |
21 C13/C15 | |
Conformance | Standards UL 62368-1 |
CSA C22.2 No 62368-1 | |
FCC part 15 subpart B | |
CE | |
EN 62368-1 | |
Environmental | Ambient Air Temperature for |
Operation | |
23...140 °F (-5...60 °C) | |
Relative Humidity 5...95 % | |
Operating altitude 0...10000 ft | |
Ambient Air Temperature for | |
Storage | |
-13...149 °F (-25...65 °C) | |
Storage Relative Humidity 5...95 % | |
Storage altitude 0...50000 ft (0.00...15240.00 m) | |
Package 1 Height 77.95 in (198 cm) | |
Package 1 width 10.31 in (26.2 cm) | |
Package 1 Length 5.20 in (13.2 cm) | |
Offer Sustainability | REACh Regulation REACh Declaration |
REACh free of SVHC Yes | |
EU RoHS Directive Compliant | |
EU RoHS Declaration | |
Mercury free Yes | |
RoHS exemption information Yes |