Anord Mardix Databar Busway

In stock
SKU:
Databar
  • 24×7 remote and on-site support
  • Multi-vendor solutions & services
  • Local billing in 33+ countries
  • Competitive Price

ENGINEERED FOR OPTIMUM SAFETY AND EFFICIENCY
The unique tap-off design also provides the essential safety element when inserting a tap-off onto a live busway system. The power contacts are engaged via a patented actuation system that not only controls the tap-off contacts but also interlocks with the switching device to ensure that no load is connected during the engaging operation.

INDUSTRY LEADING BENEFITS

  • The compact design of the DATABAR busway is ideal in situations where low ceiling height and IT / fiber conduits compete for space.
  • Safety in simplicity and scalability – there are only two DATABAR sizes: 160a-630a and 800a-1000a. The same low-profile housing accommodates both 4 and 5-pole systems while maintaining the smallest footprint design.
  • The open channel modular busway construction allows the tap-off units to be placed at any location along the busway. Tap-off designs are available to install over the joint if necessary and the whole design is aimed at flexibility and simplicity.
  • Easy installation, extension and development means that an investment in DATABAR today will still be giving you a return in years to come
  • Independently certified by ASTA to BS EN / IEC 61439-6
  • Two busway designs; DX for 160A to 630A and DX Plus for 800 to 1000A systems with 3, 4 or 5 poles in the same footprint
  • Continuous open channel permits tap-offs to be installed anywhere along the busway (IP2X)
  • Flexible extension and re-configuration with integral plug-n-play jointing system
  • A patented design feature within the tap-off unit centres around the actuator mechanism puts safety and efficiency at the forefront of the design and installation process.
  • IP3X achievable by using the channel cover strip solution
  • Available in 1m, 2m and 3m lengths as standard. Non -standard lengths also available on request
  • Optional overrated neutrals or 100% integral earth conductor
  • The busbar trunking system has also been independently tested for resistance to Arc Flash in accordance with IEC / BS EN 61641 and seismically tested to IEEE 344-2103.
Rated CurrentIn [A]
160, 250A, 400A, 630A
Rated operating voltageUe [V]600
Rated insulation voltageUi [V]1000
Frequencyf[Hz]50/60
Degree of protectionIP2X
Casing Material Aluminium
Conductor material 
Cu (99.9%) BS EN 13601
Case dimensions (4 or 5 pole systems)W x H mm165 x 47
Phase Neutral or Isolated Earth Conductor CSACSA [mm2]1457
Case Earth (PE) CSACSA [mm2]194
Weight (4 pole systems)p[kg/m]12.9
Weight (5 pole systems)p[kg/m]14.5
Rated short-time current for three phase faultIcw[kA] rms30
Allowable peak current for three phase faultIpk [kA]64.2
Rated conditional protection for three phase faultIcc [kA]50
Conditional protection peak current ratingIpk [kA]106
Impact ResistanceIKIK08