Toggle Nav

IXIa 7433 GTP Session Controller

In stock
SKU:
7433GTP
  • 24×7 remote and on-site support
  • Multi-vendor solutions & services
  • Local billing in 33+ countries
  • Competitive Price

As 4G LTE revolutionizes the use of data services for mobile users worldwide, mobile carriers are increasingly focused on ways to improve network service dependability and customer Quality of Experience (QoE). Now, the Ixia GTP Session Controller 7433 helps mobile carriers optimize the performance of vital network monitoring solutions as data traffic and session counts increase. The GSC 7433 provides intelligent traffic distribution with the ability to detect faulty or overloaded monitoring probes and redistribute the load to other probes in the cluster. Additionally, the GSC 7433 provides unprecedented scalability and network visibility by ensuring that GTP traffic related to one session is delivered to a single probe. This allows monitoring probes to focus their resources on QoE analysis instead of spending cycles attempting to reassemble GTP session traffic.

By optimizing the reliability and efficiency of monitoring probes, the GSC 7433 aids mobile carriers in the delivery of user-centric mobile services allowing them to retain and grow their subscriber base, improve ARPU and minimize operational costs. The solutions is available in two models: 2-Port, 1/10G module with extended burst protection and NEBS certification for the NTO 5236 and NTO 5273; and for larger enterprises and service providers, a 16-port 10G module with VNTag stripping and time stamping, for the NTO 5288 product. The solution offers:

  • GTP-session awareness — Enables monitoring solutions to scale by offloading the correlation of subscriber data from monitoring probes.  
  • Session Distiller — Samples and filters GTP sessions to reduce traffic sent to probes to the essential information 
  • Session Safety Net — Automatically detects probe failure and redistributes the traffic until the probe recovers.
  • Scalable, high-density solution — A right-sized monitoring solution with enough headroom for future growth.  
  • Carrier-grade robustness — Deliver uninterrupted traffic distribution in demanding telecommunication environments.  
  • Simple visual management — Focus on the business of running the network rather than spending time reading an instruction manual. 

Performance

  • 10GE Ethernet support
  • Full line-rate across all ports
  • Supports more than 50 million GTP sessions

High-Availability Features

  • NEBS Level 1 Certified Product
  • Redundant, hot-swappable power supply & fan modules
  • Local and remote alarm relay support
  • Redundant management ports
  • Craft interface for emergency out-of-band reset

Port Flexibility

  • Up to 64 10GE (SFP+) port configurations available via flexible 10GE port modules
  • 16 port ingress x 16 port egress module
  • 16 port ingress x 32 port egress module
  • 32 port ingress x 32 port egress module
  • All port licenses are included with purchase of modules

3GPP Specification Support

  • 4G LTE, UMTS, GPRS, GSM
  • GTPv1 and GTPv2

Management

  • SNMP v1, v2, v3c support
  • TACACS+ and RADIUS support (members and groups)
  • Granular access control features
  • Event logging
  • Local and remote Syslog
  • API for IT automation and control
  • Dual IP-based management ports (RJ45 ‚Äì 10/100/1000 Mbps)
Physical Specifications
Size and Weight
  • 2U high rack mountable enclosure
  • Dimensions: 17.5W x 19.125L x 3.5H (inches), 44.45W x 48.58L x 8.89H (centimeters)
  • Weight: 35.0 lb (16 kg)
Power AC
  • Input AC voltage: 90-240V AC RMS auto-switching
  • Frequency: 50-60Hz
  • Nominal power requirement: 2.36A @ 110V AC, 260W
  • Maximum power requirement: 5A @ 110V AC, 550W
  • Heat/power dissipation for system with all 64 ports on the front panel at 100% traffic load: nominally 260W/887 BTU/hour
Power DC
  • Operating input voltage: -36 to -75V DC
  • Nominal current: 5.41A @ -48V DC, 260W
  • Maximum operating input current: 11.46A @ -48V DC, 550W
  • Heat/power dissipation for system with all 64 ports on the front panel at 100% traffic load: Nominally 260W/887 BTU/hour
Operating Specifications
Temperature
  • Operating: 5C to 40C
  • Short-term: -5C to 55C (not to exceed 96 consecutive hours)
  • Short-term: with fan failure: -5C to 40C (not to exceed 96 consecutive hours)
Humidity
  • Operating: 5% to 85%, (non-condensing)
  • Short-term: 5% to 90% (non-condensing, not to exceed 96 consecutive hours)
Regulatory/Safety
North American Safety
  • UL 60950-1, 2nd Edition
  • CSA C22.2 No. 60950-1, 2nd Edition
  • GR-1089-CORE, Issue 5, August 2009
European Safety
  • EN60950-1
  • International Safety
  • CB Scheme: IEC 60950-1:2005 First Edition
RoHS Compliant
  • North American EMC o FCC part 15, Class A (USA)
    • ICES-003 Issue 4, Class A (Canada)
    • GR-1089-CORE, Issue 5, August 2009
  • European EMC o EN55022 2006 Class A (Emissions)
    • EN55024 1998 w/A2 (Immunity)
    • EN61000-3-2:2006 (Harmonics)

Custom Solutions
Competative Prices
Global Logistics